17. Lever adjustment: Connect the tool (122046) to the
second stage and the MP hose to the tool. Connect this
assembly to a Legend first stage adjusted as follows :
Legend LX: MP = 9.5 bar ± 0.5 bar
Legend LX Supreme: MP = 8.5 bar ± 0.5 bar
18. Fit the diaphragm (13) in the casing. Press all around
the edges with a finger to ensure that it is in place. Fit
the washer (14) directly in contact with the diaphragm.
19.
After tightening the diaphragm retainer (15), hold the top
of the diaphragm and gently pull it in all directions to
ensure that it is firmly in place in the housing. If not, refit
it.
20. Fit the purge button in position by ensuring that the
“ Legend “ plate is the right way up. Fit the bumper
(30) to the outer ring (2). While holding the purge button
screw the ring fully home. Use the lug spanner (129198)
to tighten the ring an additional 1/16 of a turn maximum.
21. Checking the venturi
a. Place the venturi control in the “ + “ position.
b. Press on the purge button. The regulator should
free flow
c. While the regulator is free flowing, move the control
to the “ – “ position. The free flow should stop
immediately. If it does not stop, screw the seta in
1/8 turn and try again.
d.
22. Turn off the air supply and purge the second stage.
Tighten nut (5) using a 17 mm torque wrench at 0.5
m.kg
23. Refit the mouthpiece (17) onto the casing. If it is a
Comfobite mouthpiece, check that the support section is
on top. Fit the mouthpiece strap (29) into its groove.
The collar lever should point down on the hose side.
24. If the regulator is a Legend Supreme, fit the lip shield
(36) over the mouthpiece and against the mouthpiece
strap.
Manually screw the
diaphragm retainer
(15) fully home, flat
face toward the
diaphragm. Use tool
(129001) to tighten it
an additional ¼ turn.
Put the regulator under
pressure. Slide tool
(129001) along the top
edge of the casing. In the
highest position the tool
should press on the
lever, causing an airflow.
In the lowest position the
2
nd
stage should not leak
air. Adjust the seat using
the tool until the
adjustment is correct.
Put at + and purge
Put at – to stop free flow
Note: If you have a regulator Test Bench, carry
out these tests before refitting the mouthpiece.
Instructions for the check are given in the
aragraph Final Checks