Aqua Lung LEGEND LX SUPREME Service Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
4 Legend LX Second Stage Service Manual
4. The acronyms used:
LP: Low Pressure
MP: Medium Pressure
HP: High Pressure
5. Numbers in brackets indicate the part number of the
component shown on the exploded view attached.
DISASSEMBLY PROCEDURE
1. Use two 11/16’’ spanners to block the nut (5) and to
unscrew the end nut on the hose. Remove the O-ring
from the hose nipple. Take care not to damage the O-
ring groove. Remove the O-ring from the hose threaded
end.
2.
3. Using the lug spanner (129198), unscrew the outer ring
(2). Separate the bumper (30) of the ring. Remove the
Legend push-button(16).
Slide back the hose
protectors and check that
there are no signs of
impact and that the
crimped ends are in good
condition and that they
firmly grip the hose. If
not, it should be
re
p
laced.
Note: It is not normally necessary to remove the
Legend plate (25).
Note: Before commencing disassembly, consult
the exploded view to check the reference
numbers of all parts requiring replacement.
These parts should all be replaced by new parts
and should not be re-used on the pretext that
the regulator has seen little use since its
manufacture or since its last service.
A
ttention: Use only the special tool when
removing O-rings in order to avoid damaging the
seal recess. The slightest scratch on a sealing
surface could cause a leak. If a surface should be
damaged then this part should be replaced with a
new one. Do not use any pointed instrument or
metal tool to remove O-rings.
Page view 3
1 2 3 4 5 6 7 8 9 ... 18 19

Comments to this Manuals

No comments