Aqua Lung Kronos Service Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 23
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
6 Kronos First Stage Service Manual
9. Remove the O-ring (124612) and the AE ring (119129)
10. Turn the body over to recover the valve (124624) and
the needle (127564)
11. Disassembly of the wet chamber.
Turn the body over and remove the elastomer washer
(127586). Using a 8mm allen key unscrew the adjusting
screw (127566).
12. Remove the washer (127568) and the MP spring
(127567).
Using a 32mm spanner, unscrew the wet chamber
(127588)
13. Remove the spring base (127565), the diaphragm
(119159) and the spring (127563)
14. Disassembly of the dry chamber (Kronos Supreme).
Turn the body over and using a lug spanner (129198)
unscrew the diaphragm nut (127582). Remove the
diaphragm (127579), and then the piston (127581).
15. Using a 8 mm allen key, unscrew the adjusting nut
(127566). Remove the washer (127568) and then the
spring (127567). Remove the elastomer washer
(127587).
Using a 32mm spanner, unscrew the nut (127577).
16.
Manually remove the diaphragm (119159), the spring
base
(
127565
)
and then remove the s
p
rin
g
(
127563
)
Page view 5