12 Kronos First Stage Service Manual
Table 1. Troubleshooting Guide
SYMPTOM POSSIBLE CAUSE TREATMENT
1. The HP seat (124624) is worn or
damaged.
1. Replace the HP seat.
2. The crown (127585) is damaged. 2. Replace the crown
Increase in MP
3. The O-ring (124704) is worn or
damaged.
3. Replace the O-ring
(likely to cause a second stage leak)
4. Groove on the spring block (127562)
damaged
4. Remplacer le barillet
5. O-ring (124612) is worn or damaged. 5. Replace the O-ring
6. O-ring groove on the crown on the body
is damaged
6. Replace the body
1. O-rings on the MP a and HP plugs are
worn, extruded or damaged.
1. Replace the O-ring(s)
2. The diaphragm(119159) is worn or
damaged.
2. Replace the diaphragm
External leak
3.The diaphragm (127579) is worn or
damaged.
3. Replace the diaphragm
4. The sealing face of the diaphragm is
damaged.
4. Replace the body
5. Dry chamber screw (127577) or (127583)
loose.
5. Tighten the dry chamber
6. Seat O-ring (820016) damaged 6. Replace the O-ring
7. Nose O-ring (473056) damaged 7. Replace the O-ring
8. Shutter screw seal (124703) damaged 8. Replace the O-ring
9. ACD seat seal(473057) damaged 9. Replace the O-ring
1. Cylinder valve not completely open
1. Open the valve, check the cylinder
pressure
2. Cylinder valve requires servicing 2. Try another cylinder
3. Filter (26) blocked 3. Replace the filter
Reduced airflow or significant
breathing resistance on complete
regulator.
4. The cylinder is empty 4. Charge the cylinder