8 Kronos First Stage Service Manual
5. Reassembly of the yoke version
Fit a new lubricated O-ring (124703) inside the seat.
6. Fit the nose (129207) into the seat and fit a clean
lubricated O-ring (473056) around the nose.
7. Fit the spring (129204) inside the yoke seat (127576)
then fit the shutter seat onto the spring.
8. Fit the assembly into the yoke. Introduce the cap
between the yoke and the shutter, screw the yoke screw
(127574) so that the spring is compressed. Stop
screwing when the shutter is in this position. The yoke
screw will become hard to screw.
9. Grip the assembly in a vice and then using a torque
wrench, screw the nose at 0.2m.kg in an anti-
clockwise direction.
12. Reassembly of the DIN version.
Fit the O-ring (820016) onto the DIN seat (127572).
Fit the filter (A05106) inside the seat.
4. Fit the spring block (127562) on the spring.
Screw the spring block fully home inside the body.
10. Remove the assembly
from the vice, unscrew
the yoke nut.
Check that the shutter is
about 1.5mm proud.
Check that the shutter
acts correctly by
compressing it with your
thumb.
11. Turn the assembly over
with the threaded part
uppermost. Fit the filter
(A05106) and then the
seal (820016).
Fit the washer on the
body (127575).
Manually screw the body fully home onto the
seat, ensuring that the seat is held in a vertical
p
osition. Take care that the filter and O-ring are
not dislodged from their position.