14 Kronos First Stage Service Manual
Table 3. Recommended cleaners and lubricants
LUBRICANT / CLEANER
APPLICATION
SOURCE
Christolube MCG 111
All O-rings
Aqualung, ref. 480025
Oakite #31
Acid bath for cleaning brass and stainless
steel parts.
Oakite Products, Inc.
NETALU
Acid bath for cleaning brass and stainless
steel parts.
Aqualung, ref. 455001
Diluted white vinegar
Acid bath for cleaning brass and stainless
steel parts.
Household stores
Washing-up liquid (diluted with hot water)
Degreases brass and stainless steel parts;
general cleaning of plastic and rubber
parts.
Household stores
Disinfectant STERANIOS 2%
Disinfectant for all plastic and metal parts.
Aqualung ref : 382062
Attention: Silicone parts do not require lubrication. Do not grease them. Greasing silicone
parts can change their molecular construction and cause premature degradation of the material.
Attention: Do not use hydrochloric acid for cleaning parts. Hydrochloric acid, even when well
diluted, attacks the coating of metal parts and leaves a corrosive deposit that damages plastic
parts and O-rings.