Aqua Lung SEA MK Troubleshooting Guide Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 30
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
27e
27b
27f
27g
Press retaining screw
against body and hold
Turn body to
engage threads
12
SEA MK Technical Maintenance Manual
5
2
22
c. Using a 1/8" hex key, tighten the retaining screw by
turning it clockwise until it stops. Install a new o-ring
(22) onto the threaded end of the indicator body. Thread
the pressure indicator into the upper HP port until rmly
ngertight. Use the T-handle tool (pn 053035) to tighten.
Maintain rm pressure to avoid damage to the pin gauge.
a. Install a new o-ring (22) onto the dial pressure indicator
(27). Thread the pressure indicator into the upper HP port and
torque to 45±3 in/lbs using a 7/8" crowfoot wrench.
11. Thread a new burst plug (6) into the lower por t on therst stage
body (the side opposite of the ll adapter). Attach a 3/8" socket to
a torque wrench and tighten the burst plug to 90±3 in/lbs.
12. Install new lubricated o-rings (2) into the grooves located on
either side of the center hole of the swivel port plug (1). Install a
new o-ring (3) on the threaded end of the swivel port plug.
13. Pass the threaded end of the swivel port plug through the
hose swivel, then through the spacer (5). Make sure that both
o-rings (2) are covered by the hose swivel. Thread the swivel
adapter into the rst-stage body. Attach a 3/16" hex key to a
torque wrench and tighten the swivel port plug to 60±3 in/lbs.
a. Drop a new lubricated o-ring (27c) into the pin indicator
body (27b), making sure it is properly seated in the small
recess inside the body. Drop the washer (27d) over the o-
ring, making sure it is laying at atop the o-ring.
9. SEA MK with a pin-type pressure indicator (27a):
b. Insert the spring (27e) into the indicator body and insert
the pin (27f) into the spring. Place the retaining screw
(27g) on the pin and press the retaining screw against
the indicator body. While keeping the retaining screw
pressed against the indicator body, turn the indicator
body counterclockwise to engage the screw threads.
10. SEA MK with a dial-type pressure indicator (27):
Page view 11