14 Service Manual Kronos 2nd Stage
Table 4. Torque values
N° REFERENCE
DESCRIPTION
FORCE
127606
Hear exchanger
0.5 m.kg.
Table 5. Checking specifications
TEST
INSTRUCTIONS
SPECIFICATIONS
Leak Test
160 bar < Working pressure < 200 bar
No leak
Medium Pressure
160 bar < Working pressure < 200 bar
MP at 9.5 bar ± 0.5 bar : KRONOS (all versions)
Opening effort
160 bar < Working pressure < 200 bar
Kronos (all versions) : between 2.8 mbar and 3.8
mbar
Effort / Flow
MP at 9.5 bar ± 0.5 bar : Kronos (all versions)
15 mbar maxi at 400 L/min