SYMPTOM POSSIBLE CAUSE TREATMENT
System will not remain depressurized
after valve is shut and second stage is
purged.
1. The valve seat (20) is worn or damaged. 1. Replace valve seat
2. The valve seating surface is damaged. 2. Replace body (36)
High or Unstable IP “Creep”
1. The valve seat (20) is worn or damaged. 1. Replace valve seat
2. The valve seating surface is damaged. 2. Replace body (36)
3. The main spring (35) is defective 3. Replace main spring
4. The HP seat (34) is worn or damaged. 4. Replace HP seat
5. The HP crown sealing surface is
damaged.
5. Replace body (36)
Low IP
1. Main spring (35) is weakened or
damaged.
1. Replace spring
External Air Leak
1.The piston head o-ring (31) or shaft o-ring
(33) is worn or damaged.
1. Replace o-ring (s)
2. The o-ring grooves on the piston (32)
are damaged.
2. Replace piston and o-rings
3. The piston head o-ring sealing surface in
the piston cap (30) is damaged.
3. Replace piston cap
4. The piston shaft o-ring sealing surface in
the body is damaged.
4.Replace body
Table 1: Troubleshooting Guide