6 Legend LX Second Stage Service Manual
12. Remove the o-ring (22)
from the valve body.
16. To remove the exhaust
tee (14), submerge the
box bottom with tee in
hot water (approximately
125°F) for 2 to 3 minutes.
Grasp the tee by one of
its wings and pull it off
the box bottom.
13. Insert a small 1/8” wooden dowel into the threaded end
of the valve body and push out the shuttle valve as-
sembly (26-30). Separate the shuttle valve assembly by
pulling on each end.
14. Using a ngernail, remove the LP seat (26) and small
o-ring (28) from the shuttle valve.
15. Using a medium blade screwdriver, turn the crown (21)
six to seven full turns counterclockwise. Since the crown
is o-ring sealed, it will not completely unscrew from the
valve body. Insert the pin end of the seat extractor tool
(pn 109436) into the valve body, grasp the pin and pull
the crown completely out of the valve body. Remove the
o-ring (20) from the crown.
17. Fold back the edges of
the exhaust valve (13) and
inspect underneath. The
seating surface should be
clean and free of damage.
Inspect the exhaust valve.
It should be supple and
have well dened edges.
If it looks good, there is no
need to remove it and it may be reused. If there is any
sign of deterioration, it should be replaced.
18. If you have a Legend LX
Supreme, remove the lip
shield (11). To remove the
mouthpiece clamp (10),
simply lift the lever on the
cam latch. Remove the
mouthpiece (12).
This Ends Disassembly
Before starting reassembly, perform parts
cleaning and lubrication according to the
procedures outlined in Procedure A, titled
Cleaning & Lubrication, on page 15.