Calypso First Stage Service Manual 9
Final check before use
Checking the medium pressure :
1. Screw an MP gauge (0-25 bar) into one of the MP
ports. If the gauge is not fitted with an over-pressure
valve, then it is vital that the second stage is fitted
so that it can act as an over-pressure valve in the
event of an HP leak.
2.
Connect the first stage to a cylinder charged to
200bar. Slowly open the cylinder valve to put the
regulator under pressure.
Attention: if the MP indicated rapidly exceeds
9.5bar then this indicates a HP leak. Close the
cylinder valve immediately and purge the
regulator.
Refer to Table 1. Troubleshooting Guide.
3. With the regulator under pressure, press 2 or 3
times on the purge button to produce an
airflow.
4. Check the MP reading, which should be
between 9 and 10 bar.
5. Leave the regulator under pressure for about
10 seconds – the MP should remain stable
and should not rise by more than 0.3 bar.
If the
MP rises more than 0.3 bar this indicates that there
is a leak. Refer to Table 1. Troubleshooting
Guide.
6.
Immerse the first stage completely in water to check
that there are no leaks.
Note: Do not mistake any bubbles that are
trapped in the regulator with a leak. If there is a
leak there will be a constant stream of bubbles.
When you are sure that there is no leak, close the cylinder
valve and purge the regulator. Remove the first stage from
the cylinder and refit the dust cap.
If a leak has been detected then note its source and refer to
Table 1. Troubleshooting Guide.