FIRST TO DIVE 9
Table 1. Troubleshooting Guide
SYMPTOM POSSIBLE CAUSE TREATMENT
1. MP too high
1. Refer to First stage Troubleshooting
Guide
2. The valve (19) is worn or damaged. 2. Replace the valve
Leak or free flow at 2
nd
stage
3. The seat (21) is not correctly adjusted 3. Readjust the seat
4. The lever (14) is bent 4. Replace the lever
5. The sealing face of the seat (21) is
damaged.
5. Replace the seat
6. The lever (14) adjustment is too high 6. Unscrew the Nylstop screw (12)
7. The spring (17) is damaged 7. Replace the spring
1. MP too low
1. 1. Refer to First stage
Troubleshooting Guide
Insufficient purge flow or work of
breathing too high
2. The lever adjustment is too low 2. Readjust the lever and the valve
3. MP hose obstructed 3. Clean or replace the hose
4. Le lever (14) is bent 4. Replace the lever
1. Hole in mouthpiece (3) 1. Replace the mouthpiece
2. Diaphragm (9) damaged 2. Replace the diaphragm
Water leak in second stage during
inhalation
3. Exhalation valve (4) damaged 3. Replace the valve
5. The diaphragm (9) is not correctly fitted
between the casing (1) and the washer (10)
4. Disassemble the cover and refit the
assembly correctly
6. The casing is damaged.
5. Check the sealing face of the
exhalation valve. Replace the casing
7. The O-ring (7) is damaged. 7. Replace the O-ring
Page view 8